    High Inrush Ceramic Fast Acting Micro Fuse 2A 300V 6.1x2.5 Mm SSF1200

    Ask Lasest Price
    Model Number : SSF1200
    Price : 0.03~0.035 USD/PC
    Payment Terms : T/T, Western Union
    Supply Ability : 1000000000PCS/Month
    Delivery Time : 5-7 Days
    • Product Details
    • Company Profile

    High Inrush Ceramic Fast Acting Micro Fuse 2A 300V 6.1x2.5 Mm SSF1200


    High Inrush Surface Mount Package Ceramic Fast Acting Micro Fuse 2A 300V 6.1x2.5 mm SSF1200


    Automated Equipment Production Line


    90% of the automated production equipment is crafted in-house, which greatly enhances production efficiency and the quality of our products


    Certification


    AgencyAmpere RangeAgency File Number
    UL50mA ~ 7AE340427(JDYX2)
    CUL50mA ~ 7AE340427(JDYX8)

    Specification


    CatalogAmpereVoltageBreakingNominal ColdI2TMelting
    No.RatingRatingCapacityResistance(Ohms)Integral(A2.S)
    SSF0250250mA300VAC50A@300VAC 50A@250VAC 200A@125VAC0.860.145
    SSF0300300mA0.620.162
    SSF0315315mA0.550.189
    SSF0375375mA0.470.2
    SSF0400400mA0.380.238
    SSF0500500mA0.320.275
    SSF0600600mA0.2850.47
    SSF0630630mA0.2560.566
    SSF0700700mA0.2080.805
    SSF0750750mA0.1751.24
    SSF0800800mA0.1551.88
    SSF11001A0.1483.5
    SSF11251.25A0.1024.76
    SSF11501.5A0.0856.305
    SSF12002A0.0448.95
    SSF12502.5A0.04316.025
    SSF13003A0.03321.56
    SSF13153.15A0.02922.75
    SSF13503.5A0.02727.05
    SSF14004A0.02531.808
    SSF15005A0.01940.25
    SSF16006A0.01867.245
    SSF16306.3A0.01773.55
    SSF17007A0.01576.28

    Melting Time


    % of Ampere Rating(In)Blowing Time
    100% * In4 hours Min
    200% * In120 sec Max

    Safety Decaying Factors


    Test results may differ between laboratory testing and actual circuit application, due to contacting resistance from different types of fuse clip/holder used and circuit layouts. Please refer to safety decaying factor calculation guide listed below, to ensure proper fuse functioning within 25±5°C.


    ♦ UL standard fuse: current rating (In)= the maximum steady current of circuit / 0.75

    ♦ IEC standard fuse:current rating (In)= the maximum steady current of circuit / 0.90

    ♦ JIS standard fuse: current rating (In)= the maximum steady current of circuit / 0.85


    List of Inspection Items


    Salt spray test

    Digital microscope test

    Isolation test

    Thermal shock

    Soldering heat resistance test

    Temperature raising test

    Environmental test

    Plated-thickness major material analysis


    Steps For Fuse Selection


    1)Fuse Physical Size ► 2) Safety Agency Approvals ► 3)Voltage Rating ► 4)Current Rating ► 5)Pulse ► 6)Selection for Fuse Specific Specification ► 7)Tested in the Actual Circuit


    What's the difference between the slow blow and fast acting fuse in terms of performance and application?


    A slow blow fuse is different from a fast acting fuse in its capability to withstand transient pulse currents, i.e., it can withstand the surge current upon power-on/off, thus ensuring the equipment works normally. Therefore, slow blow fuses are often called time-delay fuses. Technically, a slow blow fuse features a higher I2t value, and it requires more energy to blow, so it is more capable of withstanding pulses compared with a fast acting fuse of same rated current.


    When an overcurrent occurs in a circuit, the breaking time of a slow blow fuse takes longer than that of a fast acting fuse because of the larger I2t. Is it less protected this way as some people are worried? The answer is no. Once the circuit fails, the overcurrent will last and corresponding energy released will go beyond the I2t of the fuse until it blows out. The timing difference of slow blowing and fast acting is not significant to their protection. Slow blowing will affect the protection performance only when sensitive components existing in the protected circuit need to be protected.


    Due to the previous difference, slow blow and fast acting fuses are applied to different circuits. Fast acting fuses must be used in purely resistive circuits (no or fewer surges) or the circuits where IC and other sensitive components need to be protected, while slow blow fuses are preferably used in capacitive or sensitive circuits where surges occur upon power-on/off and power input/output. Apart from circuits for IC protection, most applications with fast acting fuses can be replaced with slow blow ones to enhance anti-surge capability. Contrarily, replacement of applications with slow blow fuses to fast acting ones may cause the fuse to break as soon as the equipment is switched on and fails to work.


    Furthermore, economic consideration is also an indirect factor for selection because a slow blow fuse is much expensive than a fast acting one.

    Quality High Inrush Ceramic Fast Acting Micro Fuse 2A 300V 6.1x2.5 Mm SSF1200 for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Guangdong Uchi Electronics Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)